go to content

Home |  nCounter Elements™ GPRs

nCounter Elements GPRs
nCounter Elements™ GPRs















REQUEST INFO

nCounter Elements™ - General Purpose Reagents

Open Architecture Digital Genomics

nCounter Elements™ is a new digital, molecular barcoding chemistry based on NanoString’s patented technology that allows users to assemble their own assays. Assays can be developed by simply combining nCounter Elements General Purpose Reagents (GPRs) with unlabeled oligonucleotides that target your genes of interest. nCounter Elements enable highly multiplexed, direct profiling of individual molecules in a single reaction without amplification* and are ideal for a range of applications requiring efficient, high-precision quantitation of tens to hundreds of target molecules across a sample set. This unique chemistry generates high-quality results from challenging samples types, such as FFPE tissue or crude cell lysates.

Product Highlights

  • Digital » Digital quantification of nucleic acids of interest
  • Multiplexed » Multiplex up to 216 custom targets per sample in a single tube
  • Simple Workflow » 3 pipetting steps per sample; no reverse transcription, no library prep,
    no amplification*
  • FFPE Compatible » Highly correlated results from Fresh Frozen and FFPE samples
  • Reproducible » Robust molecular barcoding chemistry and simple workflow minimize variability
nCounter Elements Chemistry * Single Cell assay requires reverse transcription and amplification prior to hybridization with nCounter Elements.
** Probes A and B are 65–85 bp oligonucleotide probes that may be purchased from an oligo supply company.

Video: nCounter Elements™ General Purpose Reagents

Dr. Joe Beechem explores the novel chemistry, and highlights the benefits of the new nCounter Elements General Purpose Reagents used for Laboratory Developed Tests.

nCounter Elements General Purpose Reagents (GPRs)

nCounter Elements Specifications

  • Precision
  • Sample Types
  • Single Cell
  • Ordering Information

Precision Across a Large Range of Expression

The combination of digital counting with a simple, robust workflow minimizes variability. Digital counts increase linearly over a wide dynamic range facilitating accurate fold-change determination of targets of varying expression levels.

Reproducibility and Dynamic Range

Reproducibility and Dynamic Range - nCounter Elements

Comparison of gene expression counts for 192 genes between 2 technical replicates. Replicates were hybridized with a 192-plex nCounter Elements TagSet. The data demonstrates very highly correlated counts over 4 logs of dynamic range.


Measurement Error by Expression Level (Counts)

Measurement Error By Expression Level nCounter Elements

10,000 cells were hybridized to an 192-plex nCounter Elements TagSet. Genes were grouped by level of expression and percent CV was calculated for each group. Genes expressed at less than one transcript per cell can be measured with less than 15% CV, allowing for quantitation of 2-fold changes or less even at very low levels of transcript abundance. Precision increases with expression levels, allowing for quantitation of less than 1.2-fold changes for more highly expressed genes.

Reliable Results from Challenging Sample Types

nCounter Elements GPRs enable the generation of reliable results even in challenging sample types such as Formalin-Fixed Paraffin-Embedded (FFPE) tissues or crude cell lysates. The ability to efficiently perform large studies on archival tissues and cell lines are key advantages of nCounter Elements in translational research.

Reliable Results from FFPE Tissues

FFPE and Fresh-Frozen Samples Cluster Together in Gene Expression Analysis. Twelve matched pairs of FFPE and Fresh Frozen tumor samples were analyzed with a 36-plex nCounter Elements TagSet. Each FFPE sample clusters most closely with its Fresh Frozen partner indicating that the FFPE fixation process is not confounding biological insights. Fresh Frozen datapoints were plotted against corresponding FFPE datapoints and linear regression was performed for each sample pair generating an average R2 of 0.98.


High Correlation - Purified RNA and Crude Cell Lysates

High Correlation - Purified RNA and Crude Cell Lysates

Log2 gene expression counts from 1μL crude cell lysate and 100ng purified RNA from the same sample show high correlation. Each sample was analyzed with a 192-plex nCounter Elements TagSet.

Multiplexed Target Enrichment for Ultra-Low Sample Inputs

Achieve single cell sensitivity while minimizing amplification – single tube assay provides a simple workflow & utilizes the entire sample. A Multiplexed Target Enrichment (MTE) step allows transcripts to be amplified after a reverse transcription step. MTE can amplify 216 targets from a sample in a single tube. The resulting amplified material can then be directly hybridized with nCounter Elements and target-specific probes targeting the genes of interest - no sample clean-up or sample partitioning is required.

Comparison of Analysis With and Without MTE

Multiplex target enrichment enables sensitive detection of fold changes from very low sample inputs. Fold changes observed with probes using a standard nCounter Elements hybridization and input of 100ng RNA on the x-axis and 100pg prepared with MTE prior to Elements hybridization on the y-axis.

NOTE: Results may vary depending on assay design, sample input, or other factors.

Ordering Information

Product Type Product Number Description
nCounter Elements GPR TagSet
General Purpose Reagents for 12 reactions; includes ERCCs
ELE-P1TS-012
ELE-P1TS-024
ELE-P1TS-036
ELE-P1TS-048
ELE-P1TS-060
ELE-P1TS-072
ELE-P1TS-084
ELE-P1TS-096
ELE-P1TS-108
ELE-P1TS-120
ELE-P1TS-132
ELE-P1TS-144
ELE-P1TS-156
ELE-P1TS-168
ELE-P1TS-180
ELE-P1TS-192
12 Tags
24 Tags
36 Tags
48 Tags
60 Tags
72 Tags
84 Tags
96 Tags
108 Tags
120 Tags
132 Tags
144 Tags
156 Tags
168 Tags
180 Tags
192 Tags
nCounter Elements GPR Extension TagSet
General Purpose Reagents for 12 reactions; no ERCCs
ELE-P1EX-012
ELE-P1EX-024
12 Tags
24 Tags
nCounter Elements GPR Master Kit ELE-AKIT-048
ELE-AKIT-192
48 Rxns
192 Rxns

››  Request more information

nCounter Elements GPR TagSets

A TagSet is a pool of nCounter Elements Reporter Tags and the Universal Capture Tag. Each Reporter Tag has a unique molecular barcode and tag that hybridizes to its complimentary sequence on target-specific oligonucleotide probes. The Universal Capture Tag enables the hybridized complex to be immobilized for counting. TagSets are available for analysis of 12 to 216 targets. Core TagSets are pre-mixed with ERCCs to enable analysis of 12 to 192 targets. Extension TagSets, without ERCCs, can be added to any core TagSet to expand the multiplexing capability by 12 or 24 targets.

nCounter Elements GPR Master Kits

Master Kits contain consumables and reagents for post-hybridization processing of samples. They facilitate magnetic bead purification to remove un-hybridized capture and reporter tags and also enable capture and immobilization of barcodes.


Request Information | E-mail us: info@nanostring.com | Call us: 1 888 358 6266